FX communication
Specifications 2
2-3
2
2.2.3 Computer link
Calculations to determine the approximate time until communication is complete.
1 ) Programmable controller
Computer
Communication time = Total number of characters based on dedicated protocol
*1
×
Time to send or receive one character (ms)
*2
+ Programmable controllers maximum scan time (ms)
×
3
+ Message wait (ms)
2 ) Computer
Programmable controller
Communication time = Number of total characters based on dedicated protocol
*1
×
Time to send or receive one character (ms)
*2
+ Programmable controllers maximum scan time (ms)
+ Message wait (ms)
Note:
*1 Please count the number of characters with reference section 7.4.1 and 7.4.2 and chapter 8.
*2 Please refer to the following expression for time calculation.
Time to send or receive one character = 1/baud rate
×
number of bits in character
(start bit(1) + Data length(7 or 8) + Parity bit(0 or 1) + Stop bit(1 or 2))
Example
When 1 character = 10 bits (Data length = 7, Parity bit = 1, stop bit = 1 start bit = 1),
the time is as follows.
Note;
Please refer to following table for the relation between reading word points and communication
time.
“Message time = 0ms, Maximum scan time = 20ms, Dedicated protocol format = format 1,
Command = WR, Baud rate = 9,600 or 19,200 bps”
Baud rate (bps) Time to send or receive one character (ms)
300 33.34
600 16.67
1200 8.34
2400 4.17
4800 2.08
9600 1.04
19200 0.52
Reading word points
Baud rate (bps)
9,600 19,200
10 0.3 s 0.2 s
32 0.4 s 0.3 s
64 0.5 s 0.4 s